Identifying and Minimizing Measurement Error

Much to the dismay of those in metrology, measurement error is unavoidable and can never be fully eliminated. The key is in understanding the causes of the error, and whenever possible minimizing its effects. There are three main categories that measurement error fall into: systematic, human, and random error.

 

Systematic Error

Systematic error, also referred to as statistical bias, is particularly hard to detect. Because this type of error is related to your system of measurement, it cannot be statistically analyzed. With this type of error you will get consistent, though incorrect, readings. There are a number of causes for systematic error, these can include environmental factors, inaccuracy of standards being used, test method used, faulty equipment, and theoretical errors.

The key to reducing systematic error is in standardizing your measurement procedures. This involves careful consideration of how multiple factors can invalidate your data including understanding how the environment impacts measurement, the correct way to use your equipment, and making sure that the equipment and standards you are using are appropriate for your application, in good working order and calibrated by a lab with an appropriate measurement uncertainty. The measurement uncertainty reported on a calibration certificate helps define the systematic error of a measurement process.

 

Human Error

As long as humans are taking and recording measurements, human or gross error will be unavoidable. This could range from not properly reading a device to transposing numbers when recording data. Beyond simply telling employees to be more careful, there are steps to take to minimize this type of error.

Interpolation rounding occurs when reading analog devices. When the needle falls between the smallest division markings and the user rounds the measurement to the division they think is the closest or approximates the measurement based on the reading to which it is nearest. For instance, if a user is reading a thermometer with lines marking every 5 degrees and the needle is between the 20 and 25 degree marks. One might assume that the temperature is 22 degrees or 23 degrees, but there is no way to know that for sure based on the device. Thus interpolation, can lead to errors in your measurement data in the form of poor repeatability and reproducibility. Ensuring that your devices have a high enough resolution for your application can help to prevent interpolation rounding errors and is directly related to the precision in which a measurement can be made.

Parallax error also falls into the category of human or gross error and relates to the angle from which the device is viewed. We have all probably experienced this when driving in a car. Imagine you are in the driver seat and you can clearly see that you are going 55 mph. Your passenger is in a bit of a hurry to get to your destination, they glance at the speedometer and from their vantage point to the right of the dial it appears that you are only going 50 mph. You then may or may not proceed to have an argument about whether you are driving fast enough to reach your desired location on time. This exact phenomena occurs when reading any type of analog measurement device while not standing directly in front of the dial. As you might imagine, if users were regularly standing in various locations relative to the dial when recording measurements, data could very quickly become unreliable. Occasionally, due to the position of the dial and other equipment it is impossible to stand directly in front of the dial to read it. Many devices prone to parallax error will feature a mirror on the face of the dial which makes it easier to see where the needle is truly pointing.

 

Random Error

Random error, is unfortunately just that, and completely unavoidable. Causes of random error can range from sudden changes in the atmospheric conditions, to earthquakes and solar flares, but can also occur when pushing your equipment to its limits. Often, measurement devices will exhibit this type of error in their least significant digit or LSD. For instance, multiple readings from a precision balance could be something like 0.8526g, 0.8528g, 0.8526g, and 0.8527g. While these variances in readings are beyond your control, they can be minimized by taking multiple readings and averaging results.

Whether it’s systematic error, human error, random error, or all of the above, measurement error in general is unfortunately a nuisance that all quality managers will encounter. With expertise in precision measurement since 1939, the team at Cross has years of experience in identifying these types of errors and can help you determine whether or not there may be a need for an adjustment in process. Contact us today to talk through your specific application and find out if you are doing everything possible to minimize error.

 

How Partnering With Cross Benefits Your Operation

When it comes to metrology and calibration to ensure continuing accuracy, many industrial operations find it difficult to stay on top of everything internally. That’s where Cross Company comes in. At Cross Precision Measurement, we provide industry-leading dimensional calibration services, on-site or in-lab inspection services, metrology equipment repair, and equipment for operations who rely on accurate measurements.

Whether you’re an industrial manufacturer, commercial operation, or even a lab, Cross can help. Our network of ISO 17025 accredited calibration laboratories adhere to standards set by A2LA, NTEP, NCWM, and NIST (specifically, HB44) to ensure consistent quality and accuracy. Our goal is to make sure you’re getting accurate, reliable measurements every time. Contact Cross Precision Measurement today to get started or to talk with our experts about your next project.

Latest Cross Company Resources

System integrators must test control system configurations. Ideally we thoroughly test them before systems are delivered. Simulating inputs based on outputs is a key tool to perform these tests.
July 28, 2026
Author – Chris Hardy
Cross Logo
A global leader in food ingredients provides micro-ingredient feeders to flour and corn mills to facilitate the addition of enrichments, bleaching products, and other additives. To address increasing customer requirements for precision and data logging, the manufacturer partnered with Cross to modernize these systems by retrofitting established hardware with advanced
June 30, 2026
Cross Logo
production line using servo drive automation
Maximize efficiency and precision in your automation processes. Learn how to optimize your motion control systems with Applied Motion Products from Cross Company.
June 16, 2026
Cross Logo
Stop patching and start planning. Learn how a phased 6-step roadmap for legacy control system modernization reduces risk, spreads costs, and avoids downtime.
April 9, 2026
Cross Logo
katronic logo
Learn how Cross Process Solutions utilized the KATflow 150 to solve water billing inaccuracies and identify steam leaks for a major manufacturer. Discover the advantages of non-invasive ultrasonic technology for continuous industrial processes where system downtime is not an option.
February 9, 2026
Cross Logo
katronic logo
Cross Company helped a major automotive manufacturing facility in Alabama improve their operation by replacing legacy ultrasonic flow meters. Learn More!
February 5, 2026
Cross Logo

See how our team can help improve efficiency, reduce risk, and raise quality in your process.

Share This Material

Contact our Team

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
What can we help you with today?*

Where Can We Send Your Information?

Name*
Company Location*
This field is hidden when viewing the form
This field is hidden when viewing the form
Form Type
This field is hidden when viewing the form

Hang Tight! We're Searching... Searching... Searching...

We’re looking through thousands of pages to find the most relevant information.

In the meantime, enjoy these fun facts…

Did you know… Cross Company is an ESOP (Employee Stock Ownership Plan). Our ESOP started in 1979 and as of 2006, we are 100% employee-owned! Learn more about our ESOP and how that benefits both team members and our customers.
Did you know... the precision measurement group at Cross was founded in 1939 by our current CEO's grandfather, Jim King. That's a whole lot of calibration!
Did you know... A fingerprint weighs about 50 micrograms. We know, we weighed it! The residue left from a finger can actually make a difference in weight results which is why we wear gloves when we calibrate weights. For reference, a sheet of paper is about 4.5 grams, that’s 4.5 million micrograms.
Did you know… Cross Company has grown significantly since our start in 1954. Over the years we've acquired 26 companies! Today, our five groups have expertise in everything from industrial automation to precision measurement, and industry knowledge going all the way back to 1939.