100% Employee Owned, Founded 1954

Search
Close this search box.
Cross Logo Horizontal

Technical Guide: How to Identify Flange Fittings

Contact Today   

One of the challenges for a hose user is how to identify the fitting on the end of your hydraulic hose. This particular style of fitting is referred to as a Flange Head Style Fitting. 

The most common sizes range from 1/2 inch (8) to 2 ½ inch (40). The most common styles are SAE Code 61, 62, Caterpillar and Komatsu. The three fittings illustrated in Figure 1 are all size 1“ (16).

As you can see in figure 2, what stands out most clearly is dimension C, or thickness, of the flange head. This is the easiest way to determine if you have one of the most commonly used flange fittings.

How to Identify Flange Fittings 1

Figure 1: Code 61, Code 62, Caterpillar Style

How to Identify Flange Fittings

How to Identify Flange Fittings 2

Figure 2

Once you have removed the hose assembly from the piece of equipment, use a set of calipers to accurately measure dimension F (diameter, as shown on the chart 2- A below) to identify both the size and style. Dimension C (thickness) will help you to verify your findings.

Standard or Code 61 Flanges have a pressure range that varies from 3,000 to 5,000 PSI maximum working pressure depending on the size.

  • ½, ¾ and 1 inch – 5,000 maximum psi working pressure.
  • 1 ¼ inch – 4,000 maximum psi working pressure.
  • 1 ½ & 2 inch – 3,000 maximum psi working pressure.

High pressure or Code 62 Flanges are all rated for 6,000 psi maximum working pressure. Caterpillar style flanges are designed and used only on Caterpillar equipment. Caterpillar Flanges are identical to Code 62 dimensionally except it has a thicker dimension C.

If trying to identify the fittings while the hose is still attached to equipment, refer to the figures shown below 3A, 3B, 3C, 3D, 3E and 4. Again, you will need a set of calipers to measure your center-to-center dimensions on the head of your bolts as illustrated in the pictures below. Both dimensions C & D are crucial. As you can see, measuring the rise on the Split Flange and using the chart will be a significant help in determining Code 61 or Code 62.

Visual Step-by-Step Guide

Our hose and fitting technicians have years of experience working with a range of hoses fittings and can help your team determine the best fittings for your hose. Stop by one of our hose store locations or send us a message to learn more and discuss your hose application.

See how our hose and fittings team can help improve quality, increase efficiency, and reduce risk

Contact our Team

Hang Tight! We're Searching... Searching... Searching...

We’re looking through thousands of pages to find the most relevant information.

In the meantime, enjoy these fun facts…

Did you know… Cross Company is an ESOP (Employee Stock Ownership Plan). Our ESOP started in 1979 and as of 2006, we are 100% employee-owned! Learn more about our ESOP and how that benefits both team members and our customers.
Did you know... the precision measurement group at Cross was founded in 1939 by our current CEO's grandfather, Jim King. That's a whole lot of calibration!
Did you know... A fingerprint weighs about 50 micrograms. We know, we weighed it! The residue left from a finger can actually make a difference in weight results which is why we wear gloves when we calibrate weights. For reference, a sheet of paper is about 4.5 grams, that’s 4.5 million micrograms.
Did you know… Cross Company has grown significantly since our start in 1954. Over the years we've acquired 26 companies! Today, our five groups have expertise in everything from industrial automation to precision measurement, and industry knowledge going all the way back to 1939.